Find the rack that takes what you own.

Add your equipment, and the shelves and power strips it needs. Gearome checks fit, weight and power against the makers’ own figures, and when the figures don’t fit, shows the two that decided it.

Plan a rack

Free. No account, nothing to install.

An example plan

A wall cabinet for a network closet or a small office.

Bill of materials for this plan

To buy

Owned

Fit
16.0 / 14.2 in
Weight
18.9 / 110.2 lb
Power
≥ 51.41 / 1440 W

1 conflict · fit failed · weight passed · power unconfirmed for 1 item

Tecmojo 9U Standard Wall Mount Cabinet, 450mm Deep, Glass Door
U09
U08
U07
U06
U05
U04
U03
U02
U01
StarTech 2U Cantilever Shelf2 rack unitsToo deep for the cabinet, StarTech 2U Cantilever Shelf
CyberPower PDU15B2F10R, Basic 12-Outlet 1U Rack PDUA PDU, 1 rack unit, that supplies 1440 watts.
NETGEAR GS724TA switch, 1 rack unit, that draws 13.5 watts.
StarTech 24-Port 1U Cat6 Patch PanelA patch panel, 1 rack unit.
  • Synology DS925+, 4-Bay NASStorage 6.5 inches (166 mm) tall

Shelf depth:

A U is one unit of rack height, 1.75 inches. It decides how much equipment fits.

What this rack planner checks

Three questions decide whether an item can go in your rack. Does it fit? Can the rack carry it? Is there enough power for it?

  • Fit

    16.0 in shelf the cabinet takes 14.2 in

    An item needs enough free U, a rack deep enough for it, and rails that can hold it the way it mounts.

    The depth in a rack’s name can be its outside, as this cabinet’s 450 mm is, so Gearome compares how far each item reaches behind the front rail with the rack’s mountable depth: the room from the front rail back to whatever stops the equipment. Where we don’t have that figure, the check says so.

  • Weight

    18.9 lb in the rack the cabinet is rated for 110.2 lb

    What is bolted to the rails, the shelves and what stands on them all count against the weight capacity the maker publishes.

  • Power

    ≥ 51.41 W peak draw the PDU supplies 1440 W

    Gearome adds up the peak draw of every item, in watts, and compares it with what your PDU or UPS supplies.

Not checked: heat, the cable behind the equipment, the wall, a UPS’s runtime.

What else goes in a rack

Add the shelves, PDUs and patch panels that go in the rack, and Gearome checks them with the rest. The plan names the kind of accessory it lacks, a shelf or a power source, never a product.

Our accessories guide covers the rest.

  • Shelves

    A shelf holds what cannot bolt to the rails. Each shelf is checked against what rests on it.

  • PDUs

    A PDU puts outlets in the rack: a power strip for the equipment in it. The draw is checked against what the PDU supplies.

  • Patch panels

    A patch panel is where the cables from the wall end, in a row of ports. Each one is checked for fit like anything else.

Every figure comes from the maker’s own document

Gearome takes a rack’s mountable depth from the maker’s own document, not from the depth in its name. Each product page lists the documents.

In the Tecmojo cabinet’s name
17.7 in (450 mm)
Mountable depth, from Tecmojo’s drawing
14.2 in (360 mm)

3.5 inches (90 mm) less than the depth in its name. The shelf is 16.0 inches (406 mm) deep, more than the mountable depth, so it does not fit.

See the maker’s drawing (opens in a new tab)

Your plan reaches us only when you save it

Saving is a separate step you choose. The exception is analytics: what you place and where, and the names of items you create. You can switch analytics off.

  1. Draft

    Kept in this browser only. Save to get a link.

  2. Saved

    A link anyone can open, for 30 days after your last save.

Start with what you own.